OUR SKILLS

  • DC/AC or DC/DC converters
  • Efficiency Analysis (P, U, I)
  • Harmonics distortion determination
  • Thermal management and mapping optimization (cooling system impact)
  • Lifetime (WLTP, mission profile)
  • Electrical Fault Simulation: short-circuit, Open circuit AC or DC, Overvoltage, Undervoltage
  • Validation of hardware (power) and software technological choices
  • e-motor commands development (Speed/Torque) and inverter commands (PWM)
  • Support for optimization and development of control law (Performance and Safety)
  • Benchmark analysis
  • Burn-in/COP Tests 

OUR EQUIPMENTS

  • BATTERY SIMULATOR
    - Power: up to 320 kW
    - Voltage: up to 1000V
    - Current: up to 800 A
  • CLIMATE CHAMBER
    - +90°C - 70°C
    - 95% - 5%
    xxxxx
  • E-MOTOR EMULATOR
    3 PHASES
    - Power: 320 kW (AC or DC)
    - Voltage: 735 (ph-ph) : 735 V
    - Current: up to 400 A (per phase)
  • WATER COOLING SYSTEM
    - Up to -30°C
    - Massflow: up to 20L/min
    wwww
    wwww

High frequency acquisition (up to 1 MHz) of voltage, current, speed & torque (AVL X-ion e-Power)